7 results found
Products 5
-
Kirloskar 1010 kVA HD - 1500 kVA HDPower Rating
Prime Power: 1010 kVA | 1250 kVA | 1500 kVA
Standby Power: Up to 1650 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Kirloskar
Engine Type: 4-Stroke, Turbocharged & Intercooled
No. of Cylinders: 12 / 16 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
1010 kVA: 170–185 L/hr
1250 kVA: 210–230 L/hr
1500 kVA: 260–280 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 80–85 dB @ 1 meter
Low vibration, stable heavy-duty operation
Control Panel
Advanced digital control panel with AMF / Synchronization options
Real-time monitoring of electrical and engine parameters
Load sharing and parallel operation capability
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Heavy-duty industrial base frame
Integrated or external high-capacity fuel tank options
Weather-resistant canopy / open skid configuration
Service-friendly design for large-scale maintenance
Applications
Data Centers
Hospitals & Critical Infrastructure
Large Industrial Plants
Infrastructure & Mega Projects
Continuous Prime Power Applications
Key Benefits
Designed for mission-critical operations
High reliability with minimal downtime
Efficient performance under continuous heavy loads
Suitable for synchronization and scalable power systems
-
Caterpillar 630 kVAPower Rating
Prime Power: 630 kVA
Standby Power: Up to 693 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Caterpillar (CAT)
Engine Type: 4-Stroke, Turbocharged & Aftercooled
No. of Cylinders: 6 / 8 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
630 kVA: 100–110 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 75–80 dB @ 1 meter
Low vibration, stable operation
Control Panel
Advanced digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Synchronization capability (optional)
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Heavy-duty industrial base frame
Integrated or external fuel tank options
Weather-resistant canopy / open skid configuration
Easy maintenance access
Applications
Industrial Plants
Infrastructure Projects
Commercial Complexes
Data Centers & Critical Backup
Continuous Power Requirements
Key Benefits
Reliable performance for high-load operations
Fuel-efficient for large-scale usage
Stable and consistent power output
Suitable for continuous and parallel operations
-
Cummins (Powerica) 500 kVA - 750 kVAPower Rating
Prime Power: 500 kVA | 600 kVA | 650 kVA | 750 kVA
Standby Power: Up to 825 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Cummins
Engine Type: 4-Stroke, Turbocharged & Aftercooled
No. of Cylinders: 6 / 8 / 12 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
500 kVA: 80–90 L/hr
600 kVA: 95–105 L/hr
650 kVA: 110–120 L/hr
750 kVA: 130–140 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 75–80 dB @ 1 meter
Low vibration, stable operation
Control Panel
Advanced digital control panel (AMF / Manual)
Real-time monitoring of electrical and engine parameters
Synchronization and load sharing capability (optional)
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Heavy-duty industrial base frame
Integrated or external fuel tank options
Weather-resistant canopy / open skid configuration
Easy maintenance access
Applications
Industrial Plants
Infrastructure Projects
Commercial Complexes
Data Centers & Critical Backup
Continuous Power Requirements
Key Benefits
High-capacity performance for demanding operations
Reliable and consistent power output
Fuel-efficient for large-scale usage
Suitable for continuous and parallel operations
-
Caterpillar 625 kVA - 2000 kVAPower Rating
Prime Power: 625 kVA | 750 kVA | 1000 kVA | 1250 kVA | 1500 kVA | 2000 kVA+
Standby Power: Up to 2200 kVA+
Power Factor: 0.8
Engine Specifications
Engine Make: Caterpillar (CAT)
Engine Type: 4-Stroke, Turbocharged & Aftercooled
No. of Cylinders: 8 / 12 / 16 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
625 kVA: 100–110 L/hr
750 kVA: 120–135 L/hr
1000 kVA: 170–190 L/hr
1250 kVA: 210–240 L/hr
1500 kVA: 260–300 L/hr
2000 kVA+: 320–380 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 75–85 dB @ 1 meter (model dependent)
Low vibration, stable heavy-duty operation
Control Panel
Advanced digital control panel with AMF / Synchronization options
Real-time monitoring of electrical and engine parameters
Load sharing and parallel operation capability
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Heavy-duty industrial base frame
Integrated or external fuel tank options
Weather-resistant canopy / open skid configuration
Service-friendly design for large-scale maintenance
Applications
Data Centers
Hospitals & Critical Infrastructure
Large Industrial Plants
Airports & Metro Projects
Infrastructure & Continuous Power Applications
Key Benefits
Designed for mission-critical operations
High reliability with minimal downtime
Efficient performance for continuous heavy loads
Synchronization-ready for scalable power solutions
-
Cummins (Sudhir) 650 - 2000 kVAPower Rating
Prime Power: 650 kVA | 750 kVA | 1000 kVA | 1250 kVA | 1500 kVA | 2000 kVA
Standby Power: Up to 2200 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Cummins
Engine Type: 4-Stroke, Turbocharged & Aftercooled
No. of Cylinders: 12 / 16 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
650 kVA: 110–120 L/hr
750 kVA: 130–140 L/hr
1000 kVA: 170–180 L/hr
1250 kVA: 210–230 L/hr
1500 kVA: 260–280 L/hr
2000 kVA: 320–350 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 75–85 dB @ 1 meter (model dependent)
Low vibration, stable heavy-duty operation
Control Panel
Advanced digital control panel with AMF / Synchronization options
Real-time monitoring of electrical and engine parameters
Load sharing and parallel operation capability
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Battery charging and alternator protection
Emergency stop system
Build & Design
Heavy-duty industrial base frame
High-capacity integrated or external fuel tank options
Weather-resistant canopy / open skid options
Service-friendly design for large-scale maintenance
Applications
Data Centers
Hospitals & Critical Infrastructure
Large Industrial Plants
Airports & Metro Projects
Large Events & Infrastructure Projects
Continuous Prime Power Applications
Key Benefits
Designed for mission-critical operations
High reliability with minimal downtime
Efficient performance for continuous heavy loads
Synchronization-ready for scalable power solutions
Strong service and support network