20 results found
Products 10
-
Kirloskar 82.5 kVA - 125 kVA CPCB IV+CPCB IV+ gensets meet India’s latest emission norms, offering cleaner, more efficient, and more reliable power with significantly reduced PM and NOx emissions.
Power Rating
Prime Power: 82.5 kVA | 101 kVA | 125 kVA
Standby Power: Up to 137.5 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Kirloskar
Engine Type: 4-Stroke, Turbocharged / Intercooled
No. of Cylinders: 4 Cylinder (82.5 / 101 kVA) | 6 Cylinder (125 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
82.5 kVA: 15–17 L/hr
101 kVA: 18–20 L/hr
125 kVA: 22–25 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB-compliant acoustic enclosure
Noise Level: Approx. 75–78 dB @ 1 meter
Low vibration operation
Control Panel
Digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Build & Design
Heavy-duty base frame with integrated fuel tank
Corrosion-resistant powder-coated canopy
Easy access for maintenance
Applications
Commercial Buildings
Small to Medium Industries
Construction Sites
Events & Outdoor Applications
Backup Power Solutions
Key Benefits
Proven Kirloskar engine reliability
Fuel-efficient operation
Stable and consistent power output
Easy maintenance with strong service support
-
Kirloskar 1010 kVA HD - 1500 kVA HDPower Rating
Prime Power: 1010 kVA | 1250 kVA | 1500 kVA
Standby Power: Up to 1650 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Kirloskar
Engine Type: 4-Stroke, Turbocharged & Intercooled
No. of Cylinders: 12 / 16 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
1010 kVA: 170–185 L/hr
1250 kVA: 210–230 L/hr
1500 kVA: 260–280 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 80–85 dB @ 1 meter
Low vibration, stable heavy-duty operation
Control Panel
Advanced digital control panel with AMF / Synchronization options
Real-time monitoring of electrical and engine parameters
Load sharing and parallel operation capability
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Heavy-duty industrial base frame
Integrated or external high-capacity fuel tank options
Weather-resistant canopy / open skid configuration
Service-friendly design for large-scale maintenance
Applications
Data Centers
Hospitals & Critical Infrastructure
Large Industrial Plants
Infrastructure & Mega Projects
Continuous Prime Power Applications
Key Benefits
Designed for mission-critical operations
High reliability with minimal downtime
Efficient performance under continuous heavy loads
Suitable for synchronization and scalable power systems
-
Kirloskar 82.5 kVA - 160 kVAPower Rating
Prime Power: 82.5 kVA | 101 kVA | 125 kVA | 160 kVA
Standby Power: Up to 176 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Kirloskar
Engine Type: 4-Stroke, Turbocharged / Intercooled
No. of Cylinders: 4 Cylinder (82.5 / 101 kVA) | 6 Cylinder (125 / 160 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
82.5 kVA: 15–17 L/hr
101 kVA: 18–20 L/hr
125 kVA: 22–25 L/hr
160 kVA: 30–32 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure
Noise Level: Approx. 75–78 dB @ 1 meter
Low vibration operation
Control Panel
Digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Build & Design
Heavy-duty base frame with integrated fuel tank
Corrosion-resistant powder-coated canopy
Easy access for maintenance
Applications
Commercial Buildings
Industrial Units
Construction Sites
Events & Outdoor Applications
Backup Power Solutions
Key Benefits
Proven Kirloskar engine reliability
Fuel-efficient operation
Stable and consistent power output
Easy maintenance with strong service support
-
Mahindra Powerol 75 / 82.5 / 100 / 125 kVAPower Rating
Prime Power: 75 kVA | 82.5 kVA | 100 kVA | 125 kVA
Standby Power: Up to 137.5 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Mahindra Powerol
Engine Type: 4-Stroke, Turbocharged / Intercooled
No. of Cylinders: 4 Cylinder (75 / 82.5 kVA) | 6 Cylinder (100 / 125 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
75 kVA: 14–16 L/hr
82.5 kVA: 16–18 L/hr
100 kVA: 20–22 L/hr
125 kVA: 24–27 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure
Noise Level: Approx. 75 dB @ 1 meter
Low vibration operation
Control Panel
Digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Build & Design
Heavy-duty base frame with integrated fuel tank
Corrosion-resistant powder-coated canopy
Easy access for maintenance
Applications
Commercial Buildings
Small to Medium Industries
Construction Sites
Events & Outdoor Applications
Backup Power Solutions
Key Benefits
Reliable and consistent performance
Fuel-efficient operation
Easy installation and maintenance
Strong service support network
-
Cummins (Jakson) 82.5 - 160 kVA (LHP Genset) CPCB IV+CPCB IV+ gensets meet India’s latest emission norms, offering cleaner, more efficient, and more reliable power with significantly reduced PM and NOx emissions.
Power Rating
Prime Power: 82.5 kVA | 101 kVA | 125 kVA | 160 kVA
Standby Power: Up to 176 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Cummins
Engine Type: 4-Stroke, Turbocharged / Aftercooled
No. of Cylinders: 4 Cylinder (82.5 / 101 kVA) | 6 Cylinder (125 / 160 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
82.5 kVA: 15–17 L/hr
101 kVA: 18–20 L/hr
125 kVA: 22–25 L/hr
160 kVA: 30–32 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure
Noise Level: Approx. 75 dB @ 1 meter
Low vibration operation
Control Panel
Advanced digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Robust base frame with integrated fuel tank
Powder-coated, weather-resistant canopy
Easy access for maintenance
Applications
Commercial Buildings
Small to Medium Industrial Units
Construction Sites
Events & Outdoor Applications
Backup Power Solutions
Key Benefits
Efficient performance for low to mid-load requirements
Reliable Cummins engine technology
Fuel-efficient and cost-effective operation
Easy maintenance with dependable service support
-
Cummins (Powerica) 82.5 - 140 kVA, 66 - 112kWe PrimePower Rating
Prime Power: 82.5 kVA | 101 kVA | 125 kVA | 140 kVA
Prime Power (kWe): 66 kWe – 112 kWe
Standby Power: Up to 154 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Cummins
Engine Type: 4-Stroke, Turbocharged / Aftercooled
No. of Cylinders: 4 Cylinder (82.5 / 101 kVA) | 6 Cylinder (125 / 140 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
82.5 kVA: 15–17 L/hr
101 kVA: 18–20 L/hr
125 kVA: 22–25 L/hr
140 kVA: 26–30 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure
Noise Level: Approx. 75 dB @ 1 meter
Low vibration operation
Control Panel
Advanced digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Robust base frame with integrated fuel tank
Powder-coated, weather-resistant canopy
Easy maintenance access
Applications
Construction Sites
Commercial Buildings
Offices & Retail Spaces
Events & Outdoor Applications
Backup Power Solutions
Key Benefits
Reliable Cummins engine performance
Fuel-efficient operation
Stable and consistent power output
Easy maintenance with strong service support
-
Caterpillar 625 kVA - 2000 kVAPower Rating
Prime Power: 625 kVA | 750 kVA | 1000 kVA | 1250 kVA | 1500 kVA | 2000 kVA+
Standby Power: Up to 2200 kVA+
Power Factor: 0.8
Engine Specifications
Engine Make: Caterpillar (CAT)
Engine Type: 4-Stroke, Turbocharged & Aftercooled
No. of Cylinders: 8 / 12 / 16 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
625 kVA: 100–110 L/hr
750 kVA: 120–135 L/hr
1000 kVA: 170–190 L/hr
1250 kVA: 210–240 L/hr
1500 kVA: 260–300 L/hr
2000 kVA+: 320–380 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 75–85 dB @ 1 meter (model dependent)
Low vibration, stable heavy-duty operation
Control Panel
Advanced digital control panel with AMF / Synchronization options
Real-time monitoring of electrical and engine parameters
Load sharing and parallel operation capability
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Emergency stop system
Build & Design
Heavy-duty industrial base frame
Integrated or external fuel tank options
Weather-resistant canopy / open skid configuration
Service-friendly design for large-scale maintenance
Applications
Data Centers
Hospitals & Critical Infrastructure
Large Industrial Plants
Airports & Metro Projects
Infrastructure & Continuous Power Applications
Key Benefits
Designed for mission-critical operations
High reliability with minimal downtime
Efficient performance for continuous heavy loads
Synchronization-ready for scalable power solutions
-
Cummins (Sudhir) 650 - 2000 kVAPower Rating
Prime Power: 650 kVA | 750 kVA | 1000 kVA | 1250 kVA | 1500 kVA | 2000 kVA
Standby Power: Up to 2200 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Cummins
Engine Type: 4-Stroke, Turbocharged & Aftercooled
No. of Cylinders: 12 / 16 Cylinder (model dependent)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single / Double Bearing (model dependent)
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
650 kVA: 110–120 L/hr
750 kVA: 130–140 L/hr
1000 kVA: 170–180 L/hr
1250 kVA: 210–230 L/hr
1500 kVA: 260–280 L/hr
2000 kVA: 320–350 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure (where applicable)
Noise Level: Approx. 75–85 dB @ 1 meter (model dependent)
Low vibration, stable heavy-duty operation
Control Panel
Advanced digital control panel with AMF / Synchronization options
Real-time monitoring of electrical and engine parameters
Load sharing and parallel operation capability
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Battery charging and alternator protection
Emergency stop system
Build & Design
Heavy-duty industrial base frame
High-capacity integrated or external fuel tank options
Weather-resistant canopy / open skid options
Service-friendly design for large-scale maintenance
Applications
Data Centers
Hospitals & Critical Infrastructure
Large Industrial Plants
Airports & Metro Projects
Large Events & Infrastructure Projects
Continuous Prime Power Applications
Key Benefits
Designed for mission-critical operations
High reliability with minimal downtime
Efficient performance for continuous heavy loads
Synchronization-ready for scalable power solutions
Strong service and support network
-
Cummins (Sudhir) 82.5-140 kVAPower Rating
Prime Power: 82.5 kVA | 101 kVA | 125 kVA | 140 kVA
Standby Power: Up to 154 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Cummins
Engine Type: 4-Stroke, Turbocharged / Aftercooled
No. of Cylinders: 4 Cylinder (82.5 / 101 kVA) | 6 Cylinder (125 / 140 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
82.5 kVA: 15–17 L/hr
101 kVA: 18–20 L/hr
125 kVA: 22–25 L/hr
140 kVA: 26–30 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure
Noise Level: Approx. 75 dB @ 1 meter
Low vibration design
Control Panel
Advanced digital control panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency, and engine parameters
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Battery charging alternator protection
Build & Design
Robust base frame with integrated fuel tank
Powder-coated, weather-resistant canopy
Easy access for maintenance
Applications
Construction Sites
Commercial Buildings
Industrial Units
Events & Outdoor Applications
Emergency Power Backup
Key Benefits
Proven Cummins engine reliability
Consistent performance under varying loads
Fuel-efficient operation
Strong service network and easy maintenance
-
Ashok Leyland 62.5 kVA - 82.5 kVA - 125 kVAPower Rating
Prime Power: 62.5 kVA | 82.5 kVA | 125 kVA
Standby Power: Up to 137.5 kVA
Power Factor: 0.8
Engine Specifications
Engine Make: Ashok Leyland
Engine Type: 4-Stroke, Turbocharged / Intercooled
No. of Cylinders: 4 Cylinder (62.5 / 82.5 kVA) | 6 Cylinder (125 kVA)
Cooling System: Water-cooled
Fuel Type: Diesel
Alternator Details
Type: Brushless, Single Bearing
Phase: 3 Phase
Voltage: 415V
Frequency: 50 Hz
Fuel Consumption (Approx.)
62.5 kVA: 12–14 L/hr
82.5 kVA: 16–18 L/hr
125 kVA: 24–27 L/hr
Fuel consumption may vary depending on load conditions.
Acoustic & Noise Level
CPCB compliant acoustic enclosure
Noise Level: Approx. 75 dB @ 1 meter
Anti-vibration mounting system
Control Panel
Digital Control Panel (AMF / Manual)
Real-time monitoring of voltage, current, frequency
Safety Features
Overload Protection
Short Circuit Protection
Low Oil Pressure Shutdown
High Engine Temperature Shutdown
Build & Design
Heavy-duty base frame with inbuilt fuel tank
Corrosion-resistant powder-coated canopy
Easy access doors for maintenance
Applications
Construction Sites
Industrial Operations
Commercial Buildings
Events & Outdoor Functions
Emergency Power Backup
Key Benefits
Fuel-efficient performance across load ranges
Consistent and reliable power output
Low maintenance and easy serviceability
Ideal for rental and backup requirements